CMS9000 Multi-parameter Patient Monitor

Inquire now

CMS9000 Multi-parameter Patient Monitor

Click to enlarge image

 Origin China
 Model Number CMS9000

Features  

  • Color TFT Screen, waveform up to 8 channels
  • Light and portable with build-in rechargeable battery
  • UP to 10 kinds of monitor parameters
  • Arrhythmia analysis, pace-marker detection and S-T Segment analysis
  • 72 hour storage and review of trend grams and tables, 40 second review of holographic wave forms.
  • Built-in recorder(option)
  • All-round monitor of adult ,pediatric and neonatal.
  • Electrosurgical unit and defibrillation protected
  • Standard parameters: ECG, NIBP, SPO2, Respiration,  Temperature, Pulse rate
  • Option parameters: EtCO2, CO, IBP, Thermal Printer 

 

ECG 

  • 5-lead or 3-lead selectable
  •  Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
  •  Lead selection: I; II; III; avR; avL; avF; Vx; CAL
  •  Gain selection: 12.5mm/s, 25mm/s, 50mm/s
  •  Accuracy: ?bpm or ?%, whichever is greater
  •  Protection: Withstand 4000VAC/50Hz voltage in  isolation against electrosurgical and defibrillation
  •  Calibration signal: 1mV?%
  •  Operation modes: Diagnostic, Monitor, Surgery
  •  Alarm range: Adult: 15-300bpm
  •  Pediatric/Neonatal: 15-350bpm
  •  Alarm range: -2.0mV~2.0mV
  •  S-T detection: YES, Arrhythmia analysis: YES
  •  Alarm: YES, audible and visual alarm, alarm events recallable

 

NIBP 

  • Method: Oscillometry
  • Operation modes: Manual/Automatic/STAT
  • Measurement unit: mmHg/KPa selectable
  • Measurement types: Systolic, Diastolic, Mean
  • Measurement range: Adult: 10-270mmHg
  • Over-pressure protection: YES
  • Resolution: 1mmHg
  • Accuracy: Mean error and standard deviation  per ANSI/AAMI SP-10
  • Alarm:  Systolic, Diastolic, Mean

 

SpO2 

  • Measurement range: 0-100%
  • Accuracy: ?digit (70~100%);
  • 0~69% unspecified
  • Alarm range: 0-100%

 

Respiration 

  • Method: RA-LL impedance
  • Pediatric/Neonatal: 6-150rpm
  • Alarm range: Adult: 6-120rpm
  • Pediatric/Neonatal: 6-150rpm
  • Apnea alarm: YES

 

Temperature 

  • Resolution: 0.1占쏙옙/span>
  • Channel: Dual-channel
  • Alarm range: 0-50占쏙옙/span>

     

    Option:

     

    EtCO2 

    • Measurement Mode: Side-stream or mainstream
    • Measurement range: EtCO2: 0-99mmHg
    • Accuracy: CO2 concentration
    • Apnea alarm: YES

     

    CO 

    • Method: Thermo-dilution
    •  Measurement range: CO: 0.1-20 lit./min.

     

    IBP 

    • Channel: 2 channels
    •  Pressure transducer: Sensitivity: 5( mV/V/mmHg)
    • Transducer sites: ART, PA, CVP, RAP, LAP, ICP
    • Alarm range: -10~300mmHg

Related Keywords: Multi-parameter , Patient Monitor